Answers to real questions about industrial cooling: calculations, system layouts, common mistakes and lessons from our projects.
Data-center cooling
All in topic →Absorption Chiller for Data Centers: Free Up 1,437 kW of Grid Power
A gas absorption chiller cuts a 5,000 kW data center's cooling peak from 1,667 to 230 kW and saves RUB 67M on grid connection. Payback…
Liquid Cooling for Data Centers Without a Chiller: Water to the Chip
A 5,000 kW data center without a chiller: 1.3M kWh a year instead of 10.22M, RUB 18.9M instead of 105.2M. How a closed-circuit tower…
Data Center Cooling: 5 Options for 5,000 kW and Their Annual Cost
Chillers for a 5,000 kW data center cost RUB 105.2M a year, direct-to-chip cooling RUB 18.9M. Five cooling options compared: power, gas…
Cooling towers
All in topic →Cooling Tower vs Dry Cooler: Which to Choose for Equipment Cooling
At +30 °C a cooling tower gives 26–28 °C water, a dry cooler 36–41 °C. Comparing the two on temperature, water, electricity, climate and…
How Much Water Does a Cooling Tower Use, and How to Cut Make-Up
A 1,000 m³/h cooling tower evaporates up to 12.6 m³/h and takes 16.8 m³/h of make-up. Calculating evaporation, drift and blowdown, and…
How to Choose an Industrial Cooling Tower: Open, Closed or Hybrid
An open cooling tower on a 1,000 m³/h loop takes up to 16.8 m³/h of make-up; a closed one keeps the loop clean. Choosing by temperature…
What Is a Cooling Tower? How It Works, Explained Simply
A cooling tower cools water by evaporation, losing about 1% of the flow as vapor per 7 °C of cooling. How it is built, how it works…
Chillers
All in topic →Chiller Total Cost of Ownership: Purchase vs 15 Years of Running
A chiller is 5–15 % of what you spend on cooling in 15 years; a 1,000 kW unit burns up to RUB 26 million of power a year. How to calculate…
Chiller Free Cooling: When the Compressor Stops and What It Saves
In Moscow the wet bulb is below 5 °C for 4,696 hours a year. Free cooling on 1,000 kW saves up to 1.78 million kWh a year. Thresholds…
How to Choose an Industrial Chiller: 13 Costly Mistakes
A 1,000 kW chiller running 24/7 burns RUB 26 million of power a year. 13 selection mistakes: capacity, climate, winter duty, controls and…
What Is a Chiller? How It Works, Main Parts, Layout and Types
A chiller cools water or glycol, e.g. from 12 to 7 °C, giving 2.4–6.9 kW of cooling per 1 kW of power. Main parts, the cycle step by step…
Absorption chillers and trigeneration
All in topic →Trigeneration: Power, Heat and Cooling from Gas — When It Pays Off
Trigeneration uses 85% of the gas instead of 35–40%: a gas engine makes power, its heat warms in winter and gives cooling via an…
What Is an Absorption Chiller? How It Works, When It Beats a Chiller
An absorption chiller draws 5–10 kW per 1 MW of cooling; the rest is heat from 80 °C or gas. How it works, its types, and when it beats a…
Energy efficiency
All in topic →How to Cut Industrial Cooling Costs: 8 Measures with the Numbers
Free cooling on a 1,000 kW load saves up to 1.78 million kWh a year. Eight ways to cut cooling costs: water temperature, VFDs, water, heat…
Absorption Heat Pump: How to Recover Waste Heat from 25–50 °C Water
An absorption heat pump takes 25–50 °C water from a cooling tower, adds steam or gas and delivers 60–105 °C: 42% of heat free, a third…
Manufacturing and business
All in topic →Turnkey Chiller Plant: Choosing a Single-Responsibility Contractor
A turnkey chiller plant is accepted after a 72-hour integrated test. How to pick a contractor, why piecemeal buying costs more, and 10…
Cooling Equipment Made in Russia: What Is Local, What Is Imported
Since 2014 we have built cooling towers, chillers, dry coolers, pump stations and controls in Russia. What is local, what is still…
Need advice on cooling?
Describe your site and task. Cold Energy engineers reply within one business day; complex cases I review personally. Quick question? Message Telegram @nct_admin.